The required power of the MGT-40 gas turbine starter

Document Type : Research Paper

Authors

1 Faculty of Mechanical Engineering Department Semnan University, Semnan, Iran

2 Aerospace Department Sharif University Of Technology Tehran, Iran

3 MapnaTurbine Company (TUGA), Karaj, Iran

Abstract

Determination of the starter torque-speed diagram is a major task in the design or selection of a proper gas turbine starter. In this paper, the maximum power of the MGT-40 gas turbine starter was calculated based on the dynamics of the rotor, start-up logic, and compressor map. In a recent research, the pressure ratio was assumed as a linear function of the rotor speed and the required starter power was calculated. In this study, the value is determined from the field data. To evaluate the proposed method, the results of obtained power were compared with that of the turbine performance reports. The comparison resulted in a reasonable engineering approximation.

Keywords


[1] Heckel B. G., Davis F. W., Starter Motor Sizing for Gas Turbine (Single Shaft) Driven LNG Strings, Proceedings of the 27th Turbomachinery Symposium, (1998) 7-16.
[2] Hill P., Mechanics and Thermo- dynamics of Propulsion, Second edition (1992).
[3] Mattingly J. , Heiser W., Pratt D., Aircraft Engine Design, Second Edition, (2002).
[4] Mattingly J.,Von Ohain H., Elements of Propulsion, (1989).
[5] Cohen H., Rogers G. F. C., Saravanamuttoo H. I. H., Gas Turbine Theory, Third Edition, (1991).
[6] Cengel Y. A., Boles M. A., Thermodynamics: An Engineering Approach, 7th Edition, Mcgraw-Hill, (2010), ISBN-13: 978-0073529325.
[7] Compressor Meanline Analysis of MGT-40 Gas Turbine, MAPNA Turbine (TUGA), (2015).
[8] Cumpsty N. A., Compressor Aerodynamics, 2th Edition, Krieger Pub Co, (2004), ISBN-13: 978-1575242477.
[9] Ebrahimi H., Zirak S., and Maissamy A. R., Start-Up Torque-Speed Diagram of MGT-40 Gas Turbine, Presented in 4thNational Gas Turbine Conference (GTC94), Iran University of Science and Technology (IUST), October 6-7 (2015).